BVRKP - MOBIL 600 W CYLINDER OIL

  • MSDS: BVRKP
  • Manufacturer: MOBIL OIL CORP
  • Product Name: MOBIL 600 W CYLINDER OIL
  • National Stock Number: 9150-00F019305
Product Identification

Product ID:MOBIL 600 W CYLINDER OIL
MSDS Date:10/17/1991
FSC:9150
NIIN:00F019305
MSDS Number: BVRKP

Responsible Party
MOBIL OIL CORP
PRINCETON, NJ 08540-5000
US

Emergency Phone: 609-737-4411/800-662-4525

Info Phone: 800-662-4525/609-737-4411

Cage: 6A687

Contractor
MOBIL OIL CORP
1025 PRINCETON, NJ 08540 US

Telephone: 609-737-4411

Cage: 6A687

Ingredients

SOLVENT REFINED HYDROTREATED HEAVY PARAFFINIC DISTILLATE,

CAS: 64742-54-7

RTECS: PY8035500

OSHA PEL 5 MG/CUM (MIST)


ANIMAL FATTY OIL *94-3*

CAS: 8016-28-2

Fraction By Weight: 5.08%


HYDROTREATED C25 BRIGHT STOCK BASED LUBRICATING OIL

CAS: 72623-83-7


SOLVENT-REFINED RESIDUUM, REFINED PETROLEUM OILS *94-3*

CAS: 64742-01-4


PETROLEUM HYDROCARBONS, SOLVENT DEWAXED RESIDUAL OIL

CAS: 64742-62-7

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Explanation of Carcinogenicity:NONE

First Aid

First Aid:EYES: FLUSH THOROUGHLY W/WATER. SKIN: WASH CONTACT AREAS
W/SOAP & WATER. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Flash Point Method:COC
Flash Point:540F
Lower Limits:0.6
Upper Limits:7
Extinguishing Media:CO2, FOAM, DRY CHEMICAL, WATER FOG
Fire Fighting Procedures:WEAR SCBA FOR FIRES IN ENCLOSED AREAS. USE
WATER TO COOL FIRES EXPOSED CONTAINERS. WATER SPRAY MAY BE USED TO
FLUSH SPILLS AWAY FROM EXPOSURE. (SEE SUPP)
Unusual Fire/Explosion Hazard:WATER/FOAM MAY CAUSE FROTHING.

Accidental Release

Spill Release Procedures:ABSORB ON FIRE RETARDANT TREATED
SAWDUST/DIATOMACEOUS EARTH. SHOVEL UP & DISPOSE OF AT AN
APPROPRIATE WASTE DISPOSAL FACILITY.

Handling

Handling and Storage Precautions:NONE REQUIRED

Exposure Controls

Respiratory Protection:NONE REQUIRED UNDER ORDINARY CONDITIONS OF USE &
W/ADEQUATE VENTILATION.
Ventilation:ADEQUATE
Protective Gloves:NONE REQUIRED
Eye Protection:RECOMMENDED NORMAL INDUSTRIAL TYPE
Supplemental Safety and Health
SPECIAL FIRE CONT'D: PREVENT RUNOFF FROM FIRE CONTROL/DILUTION FROM
ENTERING STREAMS, SEWERS/DRINKING WATER SUPPLY.

Chemical Properties

Boiling Pt:B.P. Text:>600F
Vapor Pres:<0.1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BROWN LIQUID W/MILD ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS
Stability Condition to Avoid:EXTREME HEAT
Hazardous Decomposition Products:CO

Disposal

Waste Disposal Methods:PRODUCT SUITABLE FOR BURNING IN AN
ENCLOSED/CONTROLLED BURNER/DISPOSED BY SUPERVISED
INCINERATION/PROCESSING BY AN APPROVED RECYCLING FACILITY/DISPOSED
OF AT GOVERNMENT APPROVED WASTE DISPOSAL FACILIT Y IAW/FEDERAL,
STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.